www.bioscience.co.uk
Sales & Support: +44 (0)1223 316 855

*

Fluorescent TrueBlot®: Anti-Rabbit IgG DyLight™ 800

Catalogue number:
18-4516-32
Size:
100 µl
Product is available in:
  • UK
  • Ireland
  • Europe
  • USA
  • Rest of World
£329.00 Shipping is calculated in checkout
Applications:

FLISA, Flow Cytometry, Immunohistochemistry, IF Microscopy, Western Blot

Antibody Host:

Mouse

Species Reactivity:

Rabbit

Antibody Isotype:

IgG

Antibody Type:

Monoclonal

Alternative Names:

Anti-Rabbit IgG DL800, TrueBlot, DL800 TrueBlot ULTRA, DyLight™ 800 TrueBlot, TrueBlot for IP/WB, TrueBlot for immunoprecipitation, TrueBlot for western blotting, Fluorescent TrueBlot, Rb TrueBlot, Infrared, IR, NIR, IR800

image 0
image 1
Product Description:

Rabbit IgG TrueBlot® is a unique DyLight™ 800 conjugated Anti-rabbit IgG monoclonal secondary antibody. Rabbit IgG TrueBlot® enables detection of immunoblotted target protein bands, without hindrance by interfering immunoprecipitating immunoglobulin heavy and light chains. It is easy to generate publication-quality IP/Fluorescent Western Blot data with Rabbit IgG TrueBlot®, simply substitute the conventional DL800 Anti-rabbit IgG blotting reagent with Fluorescent Rabbit TrueBlot® Antibody DyLight™ 800 and follow the prescribed protocol for sample preparation and immunoblotting. Ideal for Li Cor Odyssey imaging as well as other IR and near IR imaging systems. Rabbit IgG TrueBlot® is ideal for use in protocols involving immunoblotting of immunoprecipitated proteins. TrueBlot preferentially detects the non-reduced form of rabbit IgG over the reduced, SDS-denatured form of IgG. When the immunoprecipitate is fully reduced immediately prior to SDS-gel electrophoresis, reactivity of Rabbit IgG TrueBlot® with the 55 kDa heavy chains and the 23 kDa light chains of the immunoprecipitating antibody is minimized thereby eliminating interference by the heavy and light chains of the immunoprecipitating antibody in IP/Western blot applications. Applications include studies examining post-translational modification (e.g., phosphorylation or acetylation) or protein-protein interactions. Fluorescent Rabbit TrueBlot® Antibody DyLight™ 800 has been tested in dot blot, western blot, and immunoprecipitation and may also be used for detection in immunoassays that do not employ immunoprecipitation. Fluorescent Rabbit TrueBlot® Antibody DyLight™ 800 is provided as a lyophilized powder. To conserve reagent, we recommend incubating the blots from minigels in sealed bags (removing as much air as possible) with minimal volume (2-3 mLs) . If used conservatively at 2.5mLs/blot will yield enough reagent for 200 blots. Note that there are three key procedural considerations: 1. Protein A or G should not be used for the immunoprecipitation. Use of protein A or G beads with the rabbit TrueBlot will result in contaminating bands. For immunoprecipitation, Anti-rat IgG beads, or Anti-rabbit IgG beads should be used for rat or rabbit immunoprecipitating antibodies, respectively. 2. Immunoprecipitate should be completely reduced. 3. Bovine Serum Albumin, or MB-070 Blocking Buffer for Fluorescent Western Blotting, at low concentrations, should be used as the blocking protein for the immunoblot. DO NOT USE BLOTTO or MILK. All recommended dilutions for listed applications are intended as an initial recommendation, specific conditions for each protein and antibody combination should be specifically optimized by the end user. Fluorescence technology is widely used to detect proteins. However, many common visible fluorophores often result in considerable background fluorescence in the visible range. Visible fluorophores are rarely used for membrane-based protein detection because of this high background. DyLight™ 800 and DyLight™ 680 antibody and reagent conjugates are specifically designed for protein detection methods that use longer-wavelength, near-infrared (IR) fluorophores to visualize proteins in western blotting and other applications. Very low background fluorescence in the IR range provides for a much higher signal-to-noise ratio than visible fluorophores. Detection levels in the picogram range on Western blots rival the sensitivity of chemiluminescence on film. DyLight™ 800 conjugates are optimized for the Odyssey® Infrared Imaging System developed by LI-COR. DyLight™ 800 conjugates are also suitable for immunofluorescence microscopy using commercially available excitation/emission filters in the 780nm/820nm range. Dual simultaneous labeling in western blots or microscopy is achieved when DyLight™ 800 conjugates are used in conjunction with DyLight™ 680 conjugates. DyLight™ 800 and DyLight™ 680 conjugates provide an ultra-sensitive and convenient alternative

Western Blot of Fluorescent TrueBlot®: A
Western Blot of Fluorescent TrueBlot®: Anti-Rabbit IgG DyLight™ 800. Lane 1: Rabbit IgG, Non-reduced. M: Opal Pre-stained Ladder (p/n MB-210-0500). Lane 2: Rabbit IgG, Reduced. Load: 50 ng per lane. Primary antibody: none. Secondary antibody: Fluorescent TrueBlot®: Anti-Rabbit IgG DyLight™ 800 at 1:1,000 for 60 min at RT. Block: MB-070 for 30 min at RT. Predicted/Observed size: ~160 kDa for Rabbit IgG, Non-reduced.
Rabbit TrueBlot® IP / Western Blot:  Jur
Rabbit TrueBlot® IP / Western Blot: Jurkat cell lysate (0.5 ml of 1x10e7 cells/ml) was incubated with rabbit anti-human Stat1 and immunoprecipitated using Protein G, Protein A and Anti-Rabbit Ig IP Beads. Precipitate from 5x10e5 cells was subjected to electrophoresis, transferred to a PVDF membrane, and Western blotted with anti-Stat1 using Rabbit TrueBlot®: Anti-Rabbit IgG HRP