www.bioscience.co.uk
Sales & Support: +44 (0)1223 316 855

Flow cytometry compensation controls

SpectraComp compensation controls from Slingshot Biosciences are synthetic cells that mimic the optical and autofluorescence profile of lymphocytes for spectral flow cytometry analysis. Compatible with violet and UV fluorochromes, SpectraComp provides unparalleled fluorescence response and conveniently works with multiple antibody species, including mouse, rat and hamster.

HyParComp compensation controls are hydrogels designed to optimise compensation results, reduce spectral overlap associated errors, and match the single staining performance of real cells for conventional flow cytometry. Staining HyParComp yields a positive fluorescence histogram aiding in resolving the performance of the fluorophore. HyParComp also works with multiple antibody species, including mouse, rat and hamster.

Benefits of using SpectraComp
• Provides precise, reliable and repeatable results 
• High stability with multi-year shelf life
• No complex sample preparation required
• Accurate spectral unmixing for spectral analysis
• Easier experimental set up with less compensation analysis

Benefits of using HyParComp
• Unparalleled high fluorescence response
• Compatible with multiple antibody host species
• Cell-like autofluorescence for superior signal-to-noise resolution
• Compatible with UV fluorochrome, violet and tandem dyes
• Reduce errors associated with spectral overlap

SpectraComp mimics the autofluorescence profile of real cells

SpectraComp mimics the autofluorescence profile of real cells

Complete spectral signature comparison with signatures of SpectraComp used that indicated fluorophores matched those of single stained leukocytes.

SpectraComp outperforms the competitor with violet dyes

SpectraComp outperforms the competitor with violet dyes

SpectraComp beads achieve cleaner seperation of positive and negative populations when used in conjunction with violet dyes such as BV510. (Left) Cells, (middle) SpectraComp, (Right) Competitor.

QC data demonstrating HyParComp performance levels

HyParComp high performance

Complete (A) Gate the HyParComp population from the negative sample. (B) Place a gate on the negative histogram for the fluorophore of interest from the negative sample. (C) Gate the HyParComp population from a positive single-stain control sample. (D) Place a gate on the positive histogram for the fluorophore of interest from the positive single-stain control sample.

Material available for download
Application note: spectral compensation with SpectraComp
SpectraComp product flyer 
HyParComp product flyer

To discuss your requirements or to find out more, please contact our Slingshot specialist.

Products

Note: product availability depends on country - see product detail page.

Details Cat number & supplier Size Price
SpectraComp® , Unmixing Controls SSB-05-A · Slingshot Biosciences
SSB-05-A
Slingshot Biosciences
25 tests per vial £291.00
25 tests per vial
view
SpectraComp® , Unmixing Controls SSB-05-B · Slingshot Biosciences
SSB-05-B
Slingshot Biosciences
100 tests per vial £436.00
100 tests per vial
view
HyParComp™,Compensation Controls SSB-20-A · Slingshot Biosciences
SSB-20-A
Slingshot Biosciences
100 tests per vial £436.00
100 tests per vial
view
SpectraComp XT ™ , Unmixing Controls SSB-21-A · Slingshot Biosciences
SSB-21-A
Slingshot Biosciences
50 tests per vial £436.00
50 tests per vial
view
HyParComp XT™, Compensation Controls SSB-22-A · Slingshot Biosciences
SSB-22-A
Slingshot Biosciences
50 tests per vial £436.00
50 tests per vial
view