life science research products, biological research products, biotechnology
Login Register
Tel: 01223 316 855

Supplier information: Mirus

Mirus’ TransIT® reagents are unique lipid and polymer formulations that achieve superior delivery efficiency of pDNA and siRNA with minimal cytotoxic effects.

The company’s Label IT® kits employ proprietary chemistry to covalently attach labelling molecules to DNA and RNA. This simple one-step process is faster and more robust than traditional multi-step enzymatic labelling, and can be used for intracellular tracking, chromosome analysis, and microarray labelling

TransIT-2020 is Mirus Bio’s New High Performance, animal free, broad spectrum DNA transfection reagent. It provides superior transfection of plasmid DNA into mammalian cells. TransIT-2020 is suitable for both transient and stable transfection and works well in typically hard-to-transfect cell lines. TransIT-2020 is comprised of animal-origin free components and is serum compatible, eliminating the need for any culture media change after transfection.

  • Superior Performance
  • Broad Spectrum DNA Delivery - Achieve high expression in many cell types, including hard to transfect cells 
  • Animal Origin Free - TransIT®-2020 provides high performance with maximum compatibility

A limited number of samples of TransIT-2020 Transfection Reagent are available for trial. Please contact support@bioscience.co.uk for further information.

TransIT-2020 Transfection Reagent

TransIT-LT1 from Mirus Bio is our most popular broad spectrum reagent, and has been shown to efficiently deliver DNA to a range of cell types. It is suitable for many applications such as gene expression, siRNA/shRNA expression, viral production, and promoter analysis.

  • Economical reagent with no compromise in quality
  • Utilize one transfection reagent and protocol for a variety of cells
  • Low cellular toxicity—maintain cell density and reduce experimental biases.
  • High efficiency delivery
  • Deliver single or multiple plasmids

TransIT LT1

The Ingenio(TM) Solution outperforms other electroporation reagents including serum-free media and other commercially available products.  Ingenio is compatible with ALL electroporators.

  • High Efficiency Electroporation of Hard to Transfect Cells - Conduct research in biologically relevant cells
  • Compatible with All Electroporation Devices - Use your existing system; no need to purchase additional specialized equipment
  • Save Money - Reduce research costs while maximizing results
  • High Cell Viability - Minimize the risk of introducing experimental biases due to toxicity induced cellular changes
Ingenio Electroporation Products

The LabelIT miRNA Labeling Reagents are composed of a fluorophore (or biotin) attached to the positively charged Label IT linker and reactive alkylating group. The LabelIT Reagents covalently attach fluorophores (or biotin) to any reactive heteroatom in miRNAs without affecting downstream hybridization performance.

  • miRNA labeling and purification can be completed in only two hours
  • Accurate and Reproducible
  • Confidently detect all miRNAs present in a sample including those our competitors systematically miss
  • Sensitive Detection of Subfemtomole miRNA Amounts Detect low abundance miRNAs and generate complete expression profiles
  • Simple, Rapid Labeling One step, direct chemical labeling reaction completed in only two hours saving time and reducing the chances of experimental error

click here for a comparison to other labelling kits


microRNA labelling kits

TransIT-TKO is a high efficiency, low toxicity, siRNA transfection reagent for mammalian cells.

Broad Spectrum siRNA Delivery - Utilize one transfection reagent and protocol for a wide variety of cells.

  • Low cellular toxicity
  • Maintain cell density and reduce experimental biases.
  • Reproducible results
  • Obtain consistent, targeted gene knockdowns from day to day.
  • High knockdown efficiency 
  • Achieve optimal gene silencing in a large percentage of cells to ensure experimental success

TransIT-TKO

Are you currently using a broad spectrum transfection reagent, but not acheiving optimum results?

We have several transfection reagents which have been optimised for a specific cell type - why not buy a reagent where the hard work has been done for you.

Here is a comment from one of our customers: "HeLa Monster transfection reagent gave me higher numbers of transfected cells, higher levels of protein expression, and lower toxicity than any of the other reagents that I was testing in parallel (FuGene 6, Lipofectamine 2000, Effectene, and TransIT LT1)", Dr Boname, Cambridge Institute for Medical Research

Label Any DNA or RNA Template using LabelIT nucleic acid labelling reagents.. The LabelIT method is efficient, diretct, non-enzymatic labelling

Suitable for a wide range of applications

  •  One-step Chemical Method—Easily and consistently control the labeling reactions.
  • Adjustable Labeling Density—Achieve high sensitivity with optimally labeled DNA and RNA.
  • Covalent Mechanism—Permanent, non-destructive modification of nucleic acid residues is ideal for many diverse applications; labels do not impact hybridization performance.

 click here for further informtion

Copyright © 2010 Cambridge Bioscience Limited. All rights reserved.